T-KJr2 - 140,000 BTU Natural Gas Indoor Non-Condensing

This website or its third-party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the cookie policy. By closing this banner, you agree to the use of cookies. Page of 52 Go.

Table of Contents. On-Demand Water Heater. Optional Items……………………………………………………………………………………………………………………..

Takagi t kjr2 in ng manual muscle

High-Altitude Installations……………………………………………………………………………………………………. Venting Instructions…………………………………………………………………………………………………………….. Gas Supply and Gas Pipe Sizing……… Remote Controller Connections…….. Page 4: Introduction This equipment is an on-demand, tankless water heater designed to efficiently supply endless hot water for your needs. Page 6: Installation Page 7 Installation Installation and service must be performed by a qualified installer for example, a licensed plumber or gas fitter , otherwise the warranty will be void.

Page 10 Installation 5. The water plumbing pipes to the water heater heater fits inside the recess box, from unexpected adjustments. Set dipswitches shown in the table below depending on the altitude. The vent system must be sealed air tight.

A Direct vent and other than Direct Direct vent Other than Direct Vent Vent Clearance above grade, veranda, porch, deck, 1 foot 1 foot 1 foot or balcony.

Takagi T-KJr2-IN Installation Manual And Owner's Manual

Page 16 Installation Please follow all local and national codes in regards to proper termination clearances. In the absence of such codes, the following clearances can be used as guidelines. Local codes supersede these guidelines.

Ensure that any and all gas regulators used are operating properly and providing gas pressures within the specified range shown below. Page 19 Installation -Measuring inlet gas pressure- 1. Turn off all electric power to the water heater if service is to be performed. Turn the manual gas valve located on the outside of the unit clockwise the off position.

The water heater cannot perform properly without sufficient inlet gas pressure. Below are instructions on how to check the inlet gas pressure. Immediately call a licensed professional to inspect the water heater to replace any damaged parts.

Takagi T-KJr2-IN / 110 Installation Manual And Owner's Manual

Do not reverse the hot outlet and cold inlet connections to the water heater. Locate the remote controller terminal, pictured below located around the lower right-hand side of the computer board.

Takagi t kjr2 in ng manual muscle

Proper pump control helps to preserve the life of the system and saves energy as well. The Easy-Link system allows up to 4 units to manifold together. A communication cable gray color comes with each T-D2 models.

Page Computer Board Installation 4.

Takagi t kjr2 in ng manual muscle

Page 26 Installation A remote controller is not required for the Easy-Link system. Otherwise, the units will not operate properly. If a remote controller is used, the temperature on all the units in the system will automatically be set to the same temperature that is set on the remote.

Required circulation flow rates are labeled next to each application diagram. These flow rate requirements must be followed.

Takagi T-KJr2 Tankless Water Heater

Open the main gas supply valve to the unit using only your hand to avoid any spark. Never use tools.

This water heater does not have a pilot. It is equipped with an ignition device that automatically lights the burner. Do not use or store flammable products such as gasoline, solvents or adhesives in the same room or area near the water heater.

Keep flammable products: Vapors: 1.

Takagi T-KJr2U-IN-N Manual

Feel the water temperature before bathing or showering. Flow rate to activate the water heater : 0. Refer to diagram below Be sure that all openings for combustion and ventilation air are not blocked. The venting system should be checked annually for any leaks, corrosion, blockages or damage. The longer the distance or the bigger the pipes, the longer it will take to get hot water.

Check for the filter on cold water inlet.

Takagi t kjr2 in ng manual muscle

If you use the remote controller, is the power button turned on? Check if the inlet temperature is too high.

Ibm intellistation m pro 6219 manual

If there is a problem with the installation or the unit, depending on the model or if there is a remote controller installed, it will either display a numerical error code on the 7-Seg LED on the computer board for the T-D2 models only , display a blinking red LED for the T-KJr2 and T-K4 models , or the error code will display on the remote controller if it is installed.

After checking, Consult with the manufacturer. GPM Max.

Takagi t kjr2 in ng manual muscle

General terms of limited warranty: This limited warranty gives you specific legal rights, and you may also have other rights which vary from State to State. The manufacturer will honor the warranty to the original retail buyer at the original location only, and it is not transferable.

Page 52 Warranty 3 Limited Labor Coverage The manufacturer will provide for reasonable labor charges associated with warranty repairs or replacements within one 1 year from the date of purchase. The manufacturer will only pay directly to the service provider.

Warranty service must be performed by an authorized Service Representative. A list of authorized Service Representatives is available upon request. Show all indoor indoor. Comments to this Manuals Your Name:.

Ti amo da vivere pdf to jpg

Enter text from picture:. Latest comments:. Print page 1 Print document 52 pages.

Cancel Delete. Sign in OR. Don't have an account? Sign up! Restore password.